Hikvision Alarms – Physical reboot of the alarm KIT devices

AX Hub (Panel)

  • Turn ON the panel
  • Wait about 50 seconds
  • After hearing the first audio message press the reset button
  • Keep the button pressed for about 10 seconds until the audio system stops
  • The panel will reset and with this, we finish the reboot

PIR Sensor

  • Remove the front cover and remove the battery. Press the “LEARN” button and connect the battery again while still pressing the button.
  • Wait about 10 or 15 seconds and release the button.

Magnetic contact

  • Remove the front cover and remove the battery. Press the tamper button and place the connect the battery again do not release the button.

Remote control

  • Open the control and remove the battery. Press the lock button (armed) and place the button again while still pressing the button.
  • The control will blink 3 times with a red light indicating that it resets correctly.

Indoor siren

  • Remove the front cover then remove the batteries from the device, press the “LEARN” button (indicated by the image), while still pressing the button place the batteries again.
  • Wait till the light blinks 3 times with a red light indicating that it resets correctly.

Outdoor siren

  • Remove the front cover and remove the device’s batteries, press the “LEARN” button (indicated by the image), while still pressing the button place the batteries again.
  • Wait till the light blinks 3 times with a red light indicating that it resets correctly.

Water detector and temperature detector

  • Remove the front cover and remove the battery, press the “LEARN” button (indicated in the image), while still pressing the button place the batteries again.
  • Wait till the light blinks 3 times with a red light indicating that it resets correctly.

Smoke Detector

  • Remove the front cover and remove the battery from the device, press the “test” button (indicated in the image), while still pressing the button place the battery again.
  • Wait till the light blinks 3 times with a red light indicating that it resets correctly.